{"title":"Wiring Centres","description":"\u003cp\u003eHeatmiser wiring centres connect your thermostats, actuators, pump and boiler or heat pump in one box. Choose 4 or 8 zones, in 230V wired, wireless RF or 12V network versions to match your \u003ca href=\"\/collections\/thermostats-controls\"\u003ethermostats\u003c\/a\u003e. Order by 12pm for next working day UK delivery.\u003c\/p\u003e","products":[{"product_id":"heatmiser-rf-switch-two-channel-receiver","title":"Heatmiser RF-Switch Two Channel Receiver","description":"\u003cp\u003eThe Heatmiser RF-Switch is a 230V wireless receiver that turns a battery thermostat signal into a switched output. Use it to control a boiler, zone valve or hot water cylinder from a Slimline-RF or neoAir thermostat. It can also act as a wireless boiler enable link from the UH8-RF wiring centre, so there's no cable between the manifold and the boiler.\u003c\/p\u003e\u003ch3\u003eWhy installers use it\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eTwo channels:\u003c\/b\u003e control heating and hot water from one receiver.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWireless boiler link:\u003c\/b\u003e pairs with the UH8-RF wiring centre to call the boiler without a cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStatus lights:\u003c\/b\u003e output indication shows what's calling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSurface mount:\u003c\/b\u003e fits next to the boiler or cylinder.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eRF-Switch\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay load\u003c\/td\u003e\n\u003ctd\u003e3A resistive per relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal load\u003c\/td\u003e\n\u003ctd\u003e9A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x H x D)\u003c\/td\u003e\n\u003ctd\u003e108 x 90 x 24mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairs with\u003c\/td\u003e\n\u003ctd\u003eSlimline-RF, neoAir, UH8-RF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eWorks with\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/heatmiser-slimline-rf-wireless-digital-programmable-thermostat\"\u003eHeatmiser Slimline-RF\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/heatmiser-neoair-wireless-programmable-smart-thermostat\"\u003eHeatmiser neoAir\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/heatmiser-uh8-rf-8-zone-wireless-wiring-centre\"\u003eHeatmiser UH8-RF Wireless Wiring Centre\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuestions\u003c\/h3\u003e\u003cp\u003e\u003cb\u003eCan I use it on electric heating?\u003c\/b\u003e\u003cbr\u003eIt switches 3A per relay. For higher electric heating loads, see the Heatmiser RF-Switch 16A.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDo I need a wiring centre?\u003c\/b\u003e\u003cbr\u003eNo. It can work directly with a wireless thermostat. With a UH8-RF it acts as the boiler link.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eOrder by 12pm, Monday to Friday, for next working day UK delivery.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eProduct code: HM-RF-SWITCH\u003c\/p\u003e","brand":"Heatmiser","offers":[{"title":"Default Title","offer_id":59108786504015,"sku":"HM-RF-SWITCH","price":50.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1046\/4493\/6015\/files\/HM.RF-Link2_ANGLE.SCREEN__20610.1773735823_3bd41b80-8d4c-4e42-96ff-8ababd8776aa.webp?v=1792163242"},{"product_id":"heatmiser-rf-switch-16a-electric-heating-receiver","title":"Heatmiser RF-Switch 16A Electric Heating Receiver","description":"\u003cp\u003eThe Heatmiser RF-Switch 16A is a surface-mount wireless receiver for electric heating. It switches loads up to 16A, so you can control electric heaters from a wireless thermostat without running a thermostat cable.\u003c\/p\u003e\u003ch3\u003eWhy installers use it\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e16A switching:\u003c\/b\u003e handles larger electric heating loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWireless:\u003c\/b\u003e no cable between thermostat and heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSurface mount:\u003c\/b\u003e quick to fit next to the heater supply.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eNot for electric floor heating\u003c\/h3\u003e\u003cp\u003eHeatmiser state that the RF-Switch 16A has no floor limiting sensor function, so it is not designed for electric underfloor heating mats or cable. For floor heating, use a floor-sensing thermostat: the \u003ca href=\"\/products\/heatmiser-neostat-e-electric-floor-heating-smart-thermostat-230v\"\u003eHeatmiser neoStat-e\u003c\/a\u003e or \u003ca href=\"\/products\/heatmiser-slimline-e-electric-floor-heating-programmable-thermostat-230v\"\u003eHeatmiser Slimline-E\u003c\/a\u003e. Both switch up to 16A and come with a floor sensor.\u003c\/p\u003e\u003ch3\u003eWorks with\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/heatmiser-neostat-e-electric-floor-heating-smart-thermostat-230v\"\u003eHeatmiser neoStat-e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/heatmiser-slimline-e-electric-floor-heating-programmable-thermostat-230v\"\u003eHeatmiser Slimline-E\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/heatmiser-rf-switch-two-channel-receiver\"\u003eHeatmiser RF-Switch Two Channel Receiver\u003c\/a\u003e for boilers and hot water\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuestions\u003c\/h3\u003e\u003cp\u003e\u003cb\u003eCan I use it with my electric underfloor heating mat?\u003c\/b\u003e\u003cbr\u003eNo. It has no floor limiting sensor. Use the neoStat-e or Slimline-E instead.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eWho should fit it?\u003c\/b\u003e\u003cbr\u003eA qualified electrician. It switches mains electric heating loads.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eOrder by 12pm, Monday to Friday, for next working day UK delivery.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eProduct code: HM-RF-SWITCH-16A\u003c\/p\u003e","brand":"Heatmiser","offers":[{"title":"Default Title","offer_id":59108786536783,"sku":"HM-RF-SWITCH-16A","price":52.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1046\/4493\/6015\/files\/HM.RF-Switch_ANGLE.PRINT__62640.1710328859_a3445d12-43fc-4153-9f05-dcbc47f098af.webp?v=1792163244"},{"product_id":"heatmiser-uh4-4-zone-wiring-centre-230v","title":"Heatmiser UH4 4 Zone Wiring Centre 230V","description":"\u003cp\u003eThe Heatmiser UH4 is a 230V wiring centre for smaller underfloor heating systems with up to 4 zones. It links your mains room thermostats to the manifold actuators, then calls the pump and boiler when any zone needs heat. It also has a hot water output.\u003c\/p\u003e\u003ch3\u003eWhy installers use it\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eUp to 6 actuators per zone:\u003c\/b\u003e run large rooms with several loops off one thermostat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eBoiler and pump control:\u003c\/b\u003e outputs for the system boiler and the UFH pump.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRadiator option:\u003c\/b\u003e zone 4 can be used for a radiator circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNeat install:\u003c\/b\u003e DIN rail mounting and LED indication for each zone.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eUH4\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating zones\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermostats\u003c\/td\u003e\n\u003ctd\u003e230V mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuators per zone\u003c\/td\u003e\n\u003ctd\u003eUp to 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal board load\u003c\/td\u003e\n\u003ctd\u003e5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay max load\u003c\/td\u003e\n\u003ctd\u003e3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x H x D)\u003c\/td\u003e\n\u003ctd\u003e384 x 148 x 60mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiator zone option\u003c\/td\u003e\n\u003ctd\u003eZone 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot water output\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eChoosing the wiring centre\u003c\/h3\u003e\u003cp\u003eUse the UH4 for up to 4 zones. For 5 to 8 zones, choose the \u003ca href=\"\/products\/heatmiser-uh8-8-zone-wiring-centre-230v\"\u003eHeatmiser UH8 8 Zone Wiring Centre\u003c\/a\u003e. For battery thermostats, choose the \u003ca href=\"\/products\/heatmiser-uh8-rf-8-zone-wireless-wiring-centre\"\u003eHeatmiser UH8-RF Wireless Wiring Centre\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eWorks with\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/2-wire-thermal-actuator-230v\"\u003e2-Wire Thermal Actuators 230V\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/heatmiser-neostat-v3-programmable-smart-thermostat-230v\"\u003eHeatmiser neoStat V3\u003c\/a\u003e or \u003ca href=\"\/products\/heatmiser-ds1-thermostat\"\u003eDS1\u003c\/a\u003e thermostats\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/manifolds\"\u003eUFH Manifolds\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuestions\u003c\/h3\u003e\u003cp\u003e\u003cb\u003eWhich thermostats can I use?\u003c\/b\u003e\u003cbr\u003e230V mains thermostats, such as the Heatmiser neoStat V3, Edge, Touch or DS1.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eHow many actuators can I connect?\u003c\/b\u003e\u003cbr\u003eUp to 6 per zone, within the 5A total board limit.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eOrder by 12pm, Monday to Friday, for next working day UK delivery.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eProduct code: HM-UH4\u003c\/p\u003e","brand":"Heatmiser","offers":[{"title":"Default Title","offer_id":59108786569551,"sku":"HM-UH4","price":64.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1046\/4493\/6015\/files\/HM.UH4.PGV2.Angle_SCREEN__68821.1670423249_f398a111-8dd7-4d3a-9db4-673d86bb80a4.webp?v=1792163247"},{"product_id":"heatmiser-uh8-8-zone-wiring-centre-230v","title":"Heatmiser UH8 8 Zone Wiring Centre 230V","description":"\u003cp\u003eThe Heatmiser UH8 is a 230V underfloor heating wiring centre for up to 8 zones. It's the most common choice for whole-house wet UFH. Each mains room thermostat opens the actuators on its loops, and the UH8 calls the pump and boiler whenever any zone needs heat.\u003c\/p\u003e\u003ch3\u003eWhy installers use it\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e8 zones:\u003c\/b\u003e enough for most houses from one manifold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eUp to 6 actuators per zone:\u003c\/b\u003e for open-plan rooms with several loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eBoiler and pump outputs:\u003c\/b\u003e for a system boiler and the UFH pump.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRadiator option on zone 8:\u003c\/b\u003e plus DIN rail mounting and LED indication.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eUH8\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating zones\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermostats\u003c\/td\u003e\n\u003ctd\u003e230V mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuators per zone\u003c\/td\u003e\n\u003ctd\u003eUp to 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal board load\u003c\/td\u003e\n\u003ctd\u003e5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay max load\u003c\/td\u003e\n\u003ctd\u003e3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x H x D)\u003c\/td\u003e\n\u003ctd\u003e384 x 148 x 60mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiator zone option\u003c\/td\u003e\n\u003ctd\u003eZone 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eChoosing the wiring centre\u003c\/h3\u003e\u003cp\u003eFor 4 zones or fewer, the \u003ca href=\"\/products\/heatmiser-uh4-4-zone-wiring-centre-230v\"\u003eHeatmiser UH4 4 Zone Wiring Centre\u003c\/a\u003e is enough. If you want battery thermostats, use the \u003ca href=\"\/products\/heatmiser-uh8-rf-8-zone-wireless-wiring-centre\"\u003eHeatmiser UH8-RF Wireless Wiring Centre\u003c\/a\u003e. For 12V thermostats, use the \u003ca href=\"\/products\/heatmiser-uh8-n-8-zone-12v-network-wiring-centre\"\u003eHeatmiser UH8-N 12V Network Wiring Centre\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eWorks with\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/2-wire-thermal-actuator-230v\"\u003e2-Wire Thermal Actuators 230V\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/heatmiser-neostat-v3-programmable-smart-thermostat-230v\"\u003eHeatmiser neoStat V3\u003c\/a\u003e thermostats\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/heatmiser-neohub-g3\"\u003eHeatmiser neoHub G3\u003c\/a\u003e for app control\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/manifolds\"\u003eUFH Manifolds\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuestions\u003c\/h3\u003e\u003cp\u003e\u003cb\u003eWhich thermostats work with the UH8?\u003c\/b\u003e\u003cbr\u003e230V mains thermostats such as the neoStat V3, Edge, Touch, DS1 and DS1-L.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eHow many actuators can it run?\u003c\/b\u003e\u003cbr\u003eUp to 6 per zone, within the 5A total board limit.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eOrder by 12pm, Monday to Friday, for next working day UK delivery.\u003c\/b\u003e Trade account holders get trade pricing.\u003c\/p\u003e\u003cp\u003eProduct code: HM-UH8\u003c\/p\u003e","brand":"Heatmiser","offers":[{"title":"Default Title","offer_id":59108786602319,"sku":"HM-UH8","price":77.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1046\/4493\/6015\/files\/HM.UH8.Angle_SCREEN__22424.1733151817_72b89d4f-e786-4c0d-a6e5-01a8c3e0b610.webp?v=1792163251"},{"product_id":"heatmiser-uh8-rf-8-zone-wireless-wiring-centre","title":"Heatmiser UH8-RF 8 Zone Wireless Wiring Centre","description":"\u003cp\u003eThe Heatmiser UH8-RF is an 8 zone wireless wiring centre for underfloor heating. It receives signals from battery thermostats such as the Slimline-RF and neoAir, so you don't need to run thermostat cables to each room. That makes it a good fit for retrofit jobs and finished homes.\u003c\/p\u003e\u003ch3\u003eWhy installers use it\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eNo thermostat cables:\u003c\/b\u003e pairs with Slimline-RF and neoAir wireless thermostats.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWireless boiler link:\u003c\/b\u003e add an RF-Switch at the boiler instead of running a cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHot water output:\u003c\/b\u003e plus a radiator option on any zone, set in software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eUp to 6 actuators per zone:\u003c\/b\u003e with DIN rail mounting and LED indication.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eUH8-RF\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating zones\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermostats\u003c\/td\u003e\n\u003ctd\u003eWireless (Slimline-RF, neoAir)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuators per zone\u003c\/td\u003e\n\u003ctd\u003eUp to 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal board load\u003c\/td\u003e\n\u003ctd\u003e5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay max load\u003c\/td\u003e\n\u003ctd\u003e3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x H x D)\u003c\/td\u003e\n\u003ctd\u003e384 x 148 x 60mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiator zone option\u003c\/td\u003e\n\u003ctd\u003eAny zone (software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot water output\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eWorks with\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/heatmiser-neoair-wireless-programmable-smart-thermostat\"\u003eHeatmiser neoAir\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/heatmiser-slimline-rf-wireless-digital-programmable-thermostat\"\u003eHeatmiser Slimline-RF\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/heatmiser-rf-switch-two-channel-receiver\"\u003eHeatmiser RF-Switch Two Channel Receiver\u003c\/a\u003e for the boiler link\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/2-wire-thermal-actuator-230v\"\u003e2-Wire Thermal Actuators 230V\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuestions\u003c\/h3\u003e\u003cp\u003e\u003cb\u003eCan I use wired thermostats with it?\u003c\/b\u003e\u003cbr\u003eIt's designed for wireless thermostats. For wired 230V thermostats, use the Heatmiser UH8.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eHow do I extend the range?\u003c\/b\u003e\u003cbr\u003eA Heatmiser neoPlug acts as a wireless repeater for the UH8-RF.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eOrder by 12pm, Monday to Friday, for next working day UK delivery.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eProduct code: HM-UH8-RF\u003c\/p\u003e","brand":"Heatmiser","offers":[{"title":"Default Title","offer_id":59108786635087,"sku":"HM-UH8-RF","price":134.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1046\/4493\/6015\/files\/HM.UH8-RF.Angle_PRINT-manual__30410.1733151817_d062d92f-0b0d-4898-87ee-4c02be3198dd.webp?v=1792163254"},{"product_id":"heatmiser-uh8-n-8-zone-12v-network-wiring-centre","title":"Heatmiser UH8-N 8 Zone 12V Network Wiring Centre","description":"\u003cp\u003eThe Heatmiser UH8-N is an 8 zone wiring centre made for 12V thermostats such as the neoStat 12V. The wiring centre runs from 230V, but the thermostats in each room run at 12V. When any zone calls for heat, it enables the pump, valve and boiler.\u003c\/p\u003e\u003ch3\u003eWhy installers use it\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e12V thermostats:\u003c\/b\u003e pairs with the Heatmiser neoStat 12V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e8 zones:\u003c\/b\u003e for whole-house underfloor heating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eUp to 6 actuators per zone:\u003c\/b\u003e within a 5A board limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHot water output:\u003c\/b\u003e plus a radiator option on zone 8.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eUH8-N\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating zones\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermostats\u003c\/td\u003e\n\u003ctd\u003e12V (neoStat 12V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuators per zone\u003c\/td\u003e\n\u003ctd\u003eUp to 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal board load\u003c\/td\u003e\n\u003ctd\u003e5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay max load\u003c\/td\u003e\n\u003ctd\u003e3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x H x D)\u003c\/td\u003e\n\u003ctd\u003e384 x 148 x 60mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiator zone option\u003c\/td\u003e\n\u003ctd\u003eZone 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot water output\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eWorks with\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/heatmiser-neostat-12v-app-controlled-programmable-thermostat\"\u003eHeatmiser neoStat 12V\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/heatmiser-neohub-g3\"\u003eHeatmiser neoHub G3\u003c\/a\u003e for app control\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/2-wire-thermal-actuator-230v\"\u003e2-Wire Thermal Actuators 230V\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/wiring-centres\"\u003eWiring Centres\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eQuestions\u003c\/h3\u003e\u003cp\u003e\u003cb\u003eCan I use 230V thermostats with it?\u003c\/b\u003e\u003cbr\u003eNo. The UH8-N is for 12V thermostats. For 230V thermostats, use the Heatmiser UH8.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eWhat supply does it need?\u003c\/b\u003e\u003cbr\u003e230V AC. It powers the 12V thermostats itself.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eOrder by 12pm, Monday to Friday, for next working day UK delivery.\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eProduct code: HM-UH8-N\u003c\/p\u003e","brand":"Heatmiser","offers":[{"title":"Default Title","offer_id":59108787978575,"sku":"HM-UH8-N","price":144.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1046\/4493\/6015\/files\/uh8-n__64672.1733151817_0db48bd0-2046-4f54-8907-4a8dfda11bf7.webp?v=1792163256"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1046\/4493\/6015\/collections\/HM.UH8.Angle_SCREEN__22424.1733151817.webp?v=1792021075","url":"https:\/\/www.maxheatufh.com\/collections\/wiring-centres.oembed","provider":"MaxHeatUFH","version":"1.0","type":"link"}